$1.00
E. coli
Detect and quantify Escherichia coli strains.
Quantity per kit: 48 individually lyophilized reactions in 0.2mL assay tubes.
Requires GeneCount® Voyager or GeneCount® Q-96 thermocycler.
Our team responds to quote requests within 1 business day.
Description
Our GeneCount® qKit E. coli Assay kit has optimized concentrations of primers and probes that have been validated on a range of industrial sample types and the GeneCount® qPCR thermocycler devices.
Reagents come conveniently kitted in single use format, making them easier to use, with no excessive reagent handling or special storage required.
Pair any of our assay kits with the GeneCount® Voyager or GeneCount® Q-96, or take advantage of our mail-in testing services.
Specificity
The GeneCount® qPCR E. coli assay is designed to target the genes specific to E. coli strains. Each primer is designed to amplify this target and are meticulously selected using the most up-to-date reference databases. They are then screened both computationally and manually to ensure target detection with little off-target interference.
Coverage
During assay design, the genomes of thousands of different organisms are screened until each primer and probe has the right combination of specificity and breadth of target recognition.
Compatibility
Although assays are designed around samples extracted using the GeneCount® qKit Purifiers, and the analysis features of the GeneCount® instruments, they are also designed to be compatible with many standard DNA purification methods and 4+ channel qPCR instruments.
Efficiency
Through careful optimization of assay reagents, reaction parameters, and calculations integrated with the GeneCount® software, assays must demonstrate limits of detection (LOD) and quantification (LOQ) within industry actionable limits, giving you results that matter.
Robust & repeatable
Through extensive screening and analysis with real-world samples extracted from target sample matrices (water, wastewater, fuel, etc.), GeneCount® assays are capable of consistently detecting their target organism even within difficult sample types.
Additional information
Workflow | Assay |
---|
Specifications
Gene information | |
---|---|
Assay target | Escherichia coli strains |
LOD (Gene copies/reaction) | 102 |
Assay information | |
Fluorescent channels | FAM |
Cycling conditions | 95°C 3 min – 1 cycle 95°C 20s – 40 cycles 60°C 45s – 40 cycles |
Controls | Positive control [106 copies/RXN] Negative control (prepared by user) |